About MEAJO | Editorial board | Search | Ahead of print | Current Issue | Archives | Instructions to authors | Online submission | Subscribe | Advertise | Contact | Login 
Middle East African Journal of Ophthalmology Middle East African Journal of Ophthalmology
Users Online: 89   Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
ORIGINAL ARTICLE
Year : 2016  |  Volume : 23  |  Issue : 4  |  Page : 288-292

Comparison of anterior segment measurements with optical low-coherence reflectometry and partial-coherence interferometry optical biometers


Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey

Correspondence Address:
Ertugrul Can
Department of Ophthalmology, Ondokuz Mayis University Faculty of Medicine, 55139 Samsun
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-9233.194075

Rights and Permissions

Aims: To evaluate a new noncontact optical biometer using partial-coherence interferometry and to compare the clinical measurements with those obtained from the device using optical low-coherence reflectometry (OLCR). Setting and Design: Ondokuz Mayis University, Samsun, Turkey. Nonrandomized, prospective clinical trial Subjects and Methods: The study was performed on the healthy phakic eyes of volunteers in the year 2014. Measurements of axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), mean keratometry (K), and white-to-white (WTW) measurements obtained with the low-time coherence interferometry (LTCI) were compared with those obtained with the OLCR. Statistical Analysis Used: The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired t-test, and its correlation was evaluated by Pearson's coefficient. RESULTS: We examined seventy participants with a mean age of 33.06 (±9.7) (range: 19-53) years. AL measurements with LTCI and OLCR were 23.7 (±1.08) mm and 23.7 (±1.1) mm, respectively. ACD was 3.6 (±0.4) mm and 3.5 (±0.4) mm for LTCI and OLCR, respectively. The mean CCT measurements for both devices were 533 (±28) mm and 522 (±28) mm, respectively. The mean K readings measurements for LTCI and OLCR were 43.3 (±1.5) D and 43.3 (±1.5) D, respectively. The mean WTW distance measurements for both devices were 12.0 (±0.5) mm and 12.1 (±0.5) mm, respectively. Conclusions: Measurements with LTCI correlated well with those with the OLCR. These two devices showed good agreement for the measurement of all parameters.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed596    
    Printed9    
    Emailed0    
    PDF Downloaded52    
    Comments [Add]    

Recommend this journal